| SPECIFICATION | V-100 (HFC R-134A REFRIGERANT) |
V-100 MAX (HFC R-404A REFRIGERANT) |
|||
| SYSTEM NET COOLING CAPACITY UNDER ATP CONDITIONS INCLUDING 30°C AMBIENT, EUROPEAN STANDARD. | |||||
| °C | 0°C | -20°C | 0°C | -20°C | |
| Air return / on the road | W | 1530 | 575 | 2055 | 960 |
| Electric stand-by 50Hz | W | 985 | 300 | 1410 | 660 |
| SPECIFICATION | V-200 (HFC R-134A REFRIGERANT) |
V-200 MAX (HFC R-404A REFRIGERANT) |
|||
| SYSTEM NET COOLING CAPACITY UNDER ATP CONDITIONS INCLUDING 30°C AMBIENT, EUROPEAN STANDARD. | |||||
| °C | 0°C | -20°C | 0°C | -20°C | |
| Air return / on the road | W | 2255 | 945 | 2770 | 1460 |
| Electric stand-by 50Hz | W | 1850 | 685 | 1970 | 1130 |
| SPECIFICATION | V-200 MAX SPECTURM |
| Total nominal capacity on engine power at -20°C / 30°C | |
| ES100 + ES100 | 1750 W |
| Total nominal capacity on engine standby at -20°C / 30°C | |
| ES100 + ES100 | 1170 W |
| EVAPORATOR | |
| Individual capacity on engine power | |
| 0°C / 30°C | 2670 W |
| -20°C / 30°C | 1450 W |
| Individual capacity on engine standy | |
| 0°C / 30°C | 2195 W |
| -20°C / 30°C | 1125 W |
| EVAPORATOR FAN PERFORMANCE | |
| Airflow volume @ 0 Pa static pressure | |
Capacity on engine power given at 2400rpm (ATP conditions)
| SPECIFICATION | V-300 (HFC R-134A REFRIGERANT) |
V-300 MAX (HFC R-404A REFRIGERANT) |
||||
| SYSTEM NET COOLING CAPACITY UNDER ATP CONDITIONS INCLUDING 30°C AMBIENT, EUROPEAN STANDARD. | ||||||
| °C | 0°C | -20°C | 0°C | -20°C | -25°C | |
| Air return / on the road | W | 2800 | 1170 | 3355 | 1820 | 1515 |
| Electric stand-by 50Hz | W | 1800 | 725 | 1900 | 1055 | 820 |
| SPECIFICATION | V-300 MAX SPECTURM | ||
| Total nominal capacity on engine power at -20°C / 30°C | |||
| ES150 + ES150 | 1780 W | ||
| ES150 + ES100 | 1630 W*** | ||
| ES200 + ES100 | 1740 W*** | ||
| Total nominal capacity on engine standby at -20°C / 30°C | |||
| ES150 + ES150 | 1000 W | ||
| ES150 + ES100 | 915 W*** | ||
| ES200 + ES100 | 915 W*** | ||
| EVAPORATOR | ES150 MAX | ES100 MAX | ES200 MAX |
| Individual capacity on engine power | |||
| 0°C / 30°C | 2830 W | 2435 W | 2890 W |
| -20°C / 30°C | 1615 W | 1330 W | 1600 W*** |
| Individual capacity on engine standy | |||
| 0°C / 30°C | 1400 W | 1735 W | 2260 W |
| -20°C / 30°C | 930 W | 1330 W | 1250 W*** |
| EVAPORATOR FAN PERFORMANCE | |||
| Airflow volume @ 0 Pa static pressure | 760m3/h | 695m3/h | 1070m3/h |
Capacity on engine power given at 2400rpm (ATP conditions)
*** Internal Tested